Research

References

Every dataset, standard and method the platform relies on, with the place where it is used. Datasets are used under the Open Data Commons Attribution License v1.0; please cite them when you report results.

Datasets and standards

  1. [1]

    Moody GB, Mark RG. The impact of the MIT-BIH Arrhythmia Database. IEEE Engineering in Medicine and Biology Magazine. 2001;20(3):45-50.

    doi:10.1109/51.932724

    Primary dataset

  2. [2]

    Moody G, Mark R. MIT-BIH Arrhythmia Database (version 1.0.0). PhysioNet; 2005.

    doi:10.13026/C2F305

    Dataset files, ODC-By 1.0

  3. [3]

    Moody GB, Muldrow WE, Mark RG. A noise stress test for arrhythmia detectors. Computers in Cardiology. 1984;11:381-384.

    Noise robustness protocol

  4. [4]

    MIT-BIH Noise Stress Test Database (version 1.0.0). PhysioNet.

    doi:10.13026/C2HS3T

    Recorded noise (bw, em, ma)

  5. [5]

    Goldberger AL, Amaral LAN, Glass L, Hausdorff JM, Ivanov PCh, Mark RG, Mietus JE, Moody GB, Peng C-K, Stanley HE. PhysioBank, PhysioToolkit, and PhysioNet: components of a new research resource for complex physiologic signals. Circulation. 2000;101(23):e215-e220.

    doi:10.1161/01.CIR.101.23.e215

    PhysioNet resource

  6. [6]

    Pollard T, Moody BE, Lehman L, Gow B, Fernandes C, Xie C, Johnson A, Mark RG, Heldt T. PhysioNet as a global platform for biomedical research. Nature Health. 2026;1(8):792-795.

    doi:10.1038/s44360-026-00096-z

    Standard PhysioNet citation requested on the database pages

  7. [7]

    ANSI/AAMI EC57:2012. Testing and reporting performance results of cardiac rhythm and ST segment measurement algorithms. Association for the Advancement of Medical Instrumentation; 2012.

    Heartbeat classes, paced-record exclusion, reporting metrics

Heartbeat classification

  1. [8]

    de Chazal P, O’Dwyer M, Reilly RB. Automatic classification of heartbeats using ECG morphology and heartbeat interval features. IEEE Transactions on Biomedical Engineering. 2004;51(7):1196-1206.

    doi:10.1109/TBME.2004.827359

    Inter-patient DS1 / DS2 split, RR features

  2. [9]

    Luz EJdS, Schwartz WR, Cámara-Chávez G, Menotti D. ECG-based heartbeat classification for arrhythmia detection: a survey. Computer Methods and Programs in Biomedicine. 2016;127:144-164.

    doi:10.1016/j.cmpb.2015.12.008

    Review of methods and evaluation pitfalls

  3. [10]

    Kiranyaz S, Ince T, Gabbouj M. Real-time patient-specific ECG classification by 1-D convolutional neural networks. IEEE Transactions on Biomedical Engineering. 2016;63(3):664-675.

    doi:10.1109/TBME.2015.2468589

    1D CNN for beat classification

  4. [11]

    Hannun AY, Rajpurkar P, Haghpanahi M, Tison GH, Bourn C, Turakhia MP, Ng AY. Cardiologist-level arrhythmia detection and classification in ambulatory electrocardiograms using a deep neural network. Nature Medicine. 2019;25(1):65-69.

    doi:10.1038/s41591-018-0268-3

    Deep learning on ambulatory ECG

Signal processing

  1. [12]

    Pan J, Tompkins WJ. A real-time QRS detection algorithm. IEEE Transactions on Biomedical Engineering. 1985;BME-32(3):230-236.

    doi:10.1109/TBME.1985.325532

    QRS detector

  2. [13]

    Gustafsson F. Determining the initial states in forward-backward filtering. IEEE Transactions on Signal Processing. 1996;44(4):988-992.

    doi:10.1109/78.492552

    Edge transients in zero-phase filtering

  3. [14]

    Welch P. The use of fast Fourier transform for the estimation of power spectra: a method based on time averaging over short, modified periodograms. IEEE Transactions on Audio and Electroacoustics. 1967;15(2):70-73.

    doi:10.1109/TAU.1967.1161901

    Power spectral density

  4. [15]

    Bristow-Johnson R. Audio EQ Cookbook. W3C Audio Working Group Note.

    w3.org/TR/audio-eq-cookbook

    Second-order section formulas (bilinear transform with pre-warping)

Machine learning

  1. [16]

    Breiman L. Random forests. Machine Learning. 2001;45(1):5-32.

    doi:10.1023/A:1010933404324

    Random Forest, permutation importance

  2. [17]

    Cortes C, Vapnik V. Support-vector networks. Machine Learning. 1995;20(3):273-297.

    doi:10.1007/BF00994018

    Support vector machine

  3. [18]

    Rahimi A, Recht B. Random features for large-scale kernel machines. Advances in Neural Information Processing Systems 20 (NIPS 2007). 2007:1177-1184.

    RBF kernel approximation

  4. [19]

    Shalev-Shwartz S, Singer Y, Srebro N, Cotter A. Pegasos: primal estimated sub-gradient solver for SVM. Mathematical Programming. 2011;127(1):3-30.

    doi:10.1007/s10107-010-0420-4

    Primal SVM training

  5. [20]

    Kingma DP, Ba J. Adam: a method for stochastic optimization. International Conference on Learning Representations; 2015.

    arXiv:1412.6980

    CNN optimiser

  6. [21]

    Ioffe S, Szegedy C. Batch normalization: accelerating deep network training by reducing internal covariate shift. International Conference on Machine Learning; 2015.

    arXiv:1502.03167

    CNN normalisation layers

  7. [22]

    Srivastava N, Hinton G, Krizhevsky A, Sutskever I, Salakhutdinov R. Dropout: a simple way to prevent neural networks from overfitting. Journal of Machine Learning Research. 2014;15:1929-1958.

    CNN regularisation

  8. [23]

    He H, Garcia EA. Learning from imbalanced data. IEEE Transactions on Knowledge and Data Engineering. 2009;21(9):1263-1284.

    doi:10.1109/TKDE.2008.239

    Class weighting and balanced sampling

  9. [24]

    Guo C, Pleiss G, Sun Y, Weinberger KQ. On calibration of modern neural networks. International Conference on Machine Learning; 2017.

    arXiv:1706.04599

    Temperature scaling of SVM scores

  10. [25]

    Smilkov D, Thorat N, Assogba Y, et al. TensorFlow.js: machine learning for the web and beyond. Proceedings of Machine Learning and Systems (SysML); 2019.

    arXiv:1901.05350

    In-browser CNN training on WebGL

Explainability

  1. [26]

    Selvaraju RR, Cogswell M, Das A, Vedantam R, Parikh D, Batra D. Grad-CAM: visual explanations from deep networks via gradient-based localization. IEEE International Conference on Computer Vision (ICCV); 2017:618-626.

    doi:10.1109/ICCV.2017.74

    Grad-CAM

  2. [27]

    Sundararajan M, Taly A, Yan Q. Axiomatic attribution for deep networks. International Conference on Machine Learning; 2017.

    arXiv:1703.01365

    Integrated Gradients

  3. [28]

    Zeiler MD, Fergus R. Visualizing and understanding convolutional networks. European Conference on Computer Vision (ECCV); 2014. LNCS 8689:818-833.

    doi:10.1007/978-3-319-10590-1_53

    Occlusion sensitivity

  4. [29]

    Simonyan K, Vedaldi A, Zisserman A. Deep inside convolutional networks: visualising image classification models and saliency maps. 2013.

    arXiv:1312.6034

    Gradient-based saliency

Statistics

  1. [30]

    Efron B, Tibshirani RJ. An Introduction to the Bootstrap. New York: Chapman & Hall; 1993.

    Percentile bootstrap intervals

  2. [31]

    McNemar Q. Note on the sampling error of the difference between correlated proportions or percentages. Psychometrika. 1947;12(2):153-157.

    doi:10.1007/BF02295996

    Paired model comparison

  3. [32]

    Dietterich TG. Approximate statistical tests for comparing supervised classification learning algorithms. Neural Computation. 1998;10(7):1895-1923.

    doi:10.1162/089976698300017197

    Choice of significance test

  4. [33]

    Gorodkin J. Comparing two K-category assignments by a K-category correlation coefficient. Computational Biology and Chemistry. 2004;28(5-6):367-374.

    doi:10.1016/j.compbiolchem.2004.09.006

    Multi-class Matthews correlation

  5. [34]

    Cohen J. A coefficient of agreement for nominal scales. Educational and Psychological Measurement. 1960;20(1):37-46.

    doi:10.1177/001316446002000104

    Cohen’s kappa

  6. [35]

    Press WH, Teukolsky SA, Vetterling WT, Flannery BP. Numerical Recipes in C: The Art of Scientific Computing. 2nd ed. Cambridge University Press; 1992.

    Complementary error function approximation

Academic research platform. Not a clinically validated diagnostic device; never use its output for diagnosis or treatment.

Data: MIT-BIH Arrhythmia and Noise Stress Test databases (PhysioNet, ODC-By 1.0).

Made with Modulify