Data

Dataset explorer

The MIT-BIH Arrhythmia Database contains 48 approximately half-hour, two-channel ambulatory ECG recordings from 47 subjects, digitised at 360 samples per second per channel with 11-bit resolution over a 10 mV range. Every statistic below is computed live from the PhysioNet header and annotation files.
Reading headers and annotations from PhysioNet0 / 48

Records

48

About 30 minutes each, two leads (usually MLII plus V1, V2, V4 or V5)

Subjects

47

Records 201 and 202 come from the same subject

Annotated beats

-

Beat annotations mapped to AAMI EC57 classes

Sampling

360 Hz

11-bit resolution over 10 mV

AAMI class composition

Annotated beats per class in each partition of the selected split. The imbalance (N dominates, F is rare) is why per-class metrics matter.

Patient-level split

Inter-patient evaluation after de Chazal et al. (2004). Paced records are excluded.

No subject contributes to both partitions (22 training and 21 test subjects).

DS1, training (22)

101 106 108 109 112 114 115 116 118 119 122 124 201 203 205 207 208 209 215 220 223 230

DS2, test (21)

100 103 105 111 113 117 121 123 200 210 212 213 214 219 221 222 228 231 232 233 234

Excluded

  • 102 · Paced record (excluded per AAMI EC57)
  • 104 · Paced record (excluded per AAMI EC57)
  • 107 · Paced record (excluded per AAMI EC57)
  • 217 · Paced record (excluded per AAMI EC57)
  • 202 · Same subject as record 201 (training set); removed to keep partitions subject-disjoint

In the training lab, a few DS1 patients are additionally held out for validation and early stopping, so the test partition is never used for any model decision.

Records

Select a record to view its waveform, annotations and rhythm.
RecordPartitionSubjectLeadsNSVFQMean HRRhythms

Sources and licence

MIT-BIH Arrhythmia Database, version 1.0.0, doi:10.13026/C2F305. Moody GB, Mark RG. The impact of the MIT-BIH Arrhythmia Database. IEEE Engineering in Medicine and Biology Magazine 2001;20(3):45-50. Distributed by PhysioNet under the Open Data Commons Attribution License v1.0.

MIT-BIH Noise Stress Test Database, version 1.0.0, doi:10.13026/C2HS3T, used for the robustness experiments. Moody GB, Muldrow WE, Mark RG. A noise stress test for arrhythmia detectors. Computers in Cardiology 1984;11:381-384. Open Data Commons Attribution License v1.0.

Academic research platform. Not a clinically validated diagnostic device; never use its output for diagnosis or treatment.

Data: MIT-BIH Arrhythmia and Noise Stress Test databases (PhysioNet, ODC-By 1.0).